Your Equation

Library / Heat transfer and thermal systems / HTS-23

Heat transfer and thermal systems

Lumped body with constant internal power

Temperature of a lumped body of capacitance C with constant generated power P and conductance G to ambient Ta.

Ref
HTS-23
Rev
v1
Field
Heat transfer and thermal systems
Result
T [K]

A lumped body with constant internal power P, capacitance C and conductance G to ambient follows T = Ti + (Ta + P/G − Ti)[1 − exp(−Gt/C)]. It heads for the steady value Ta + P/G with time constant C/G. About 63 % of the change is complete after one time constant and 99 % after about five. It needs small internal gradients.

Temperature of a lumped body of capacitance C with constant generated power P and conductance G to ambient Ta. It relaxes exponentially towards Ta + P/G with time constant C/G.

Calculator

Solve for
K
K
2501,000
K
2501,000
W
0100,000
W/K
0.011,000
J/K
11,000,000
s
0100,000
  • Steady-state temperature, Ta + P/G310 K
  • Time constant, C/G100 s
  • Fraction of the way to steady state, 1 − exp(−Gt/C)0.6321

What drives the result

Each variable is moved across its typical range while the others stay at the values above. The longest bar is the key driver.

Body temperature (K) current value 306.3 K
PConstant internal powerKey driver
29412,900
TaAmbient temperature
281755
TiInitial temperature
288564
GConductance to ambient
290320
tTime
300310
CThermal capacitance
300310
  • After 100 s the body is at 306.3 K, 63.2 % of the way to its steady value of 310 K.
  • The time constant is 100 s, so the body needs about 500 s to settle within 1 % of the steady state.
Chart data as tables

Ranked variables

VariableTypical rangeLowest resultHighest resultSwing (K)Local stepChange in result
P Constant internal power0 to 100,000 W293.712,94012,640+10%+0.413 %
Ta Ambient temperature250 to 1,000 K281755.1474.1+10%+5.98 %
Ti Initial temperature250 to 1,000 K287.9563.8275.9+10%+3.6 %
G Conductance to ambient0.01 to 1,000 W/K290.132029.86+10%−0.282 %
t Time0 to 100,000 s30031010+10%+0.114 %
C Thermal capacitance1 to 1,000,000 J/K3003109.995+10%−0.114 %

Sweep of Time

Time (s)Body temperature (K)
0300
12,500310
25,000310
37,500310
50,000310
62,500310
75,000310
87,500310
100,000310

Sweep one variable

Body temperature (K)Hover, touch, or use the arrow keys on the chart
300302304306308310 020k40k60k80k100k Time (s) now 306.3

Variables and how each one contributes

T

Body temperature

Result · K

What the equation gives you. Everything else feeds it.

Ti

Initial temperature

K · typical 250 to 1,000

The initial temperature, in K. A higher start raises the temperature early on, but the final value is unchanged. Raising it by 10 % (to 330) moves the result by +3.6 %, from 306.3 to 317.4 K.

Ta

Ambient temperature

K · typical 250 to 1,000

The ambient temperature, in K. Raises the steady value and the path towards it. Raising it by 10 % (to 319) moves the result by +5.98 %, from 306.3 to 324.7 K.

P

Constant internal power

W · typical 0 to 100,000

The constant internal power, in W. Raises the steady-state rise in direct proportion. Raising it by 10 % (to 110) moves the result by +0.413 %, from 306.3 to 307.6 K.

G

Conductance to ambient

W/K · typical 0.01 to 1,000

The conductance to ambient, in W/K. A higher conductance lowers the steady value and shortens the time constant. Raising it by 10 % (to 5.5) moves the result by −0.282 %, from 306.3 to 305.5 K.

C

Thermal capacitance

J/K · typical 1 to 1,000,000

The thermal capacitance, in J/K. A larger capacitance slows the response. Raising it by 10 % (to 550) moves the result by −0.114 %, from 306.3 to 306 K.

t

Time

s · typical 0 to 100,000

The time, in s. More time moves the temperature towards the steady value. Raising it by 10 % (to 110) moves the result by +0.114 %, from 306.3 to 306.7 K.

Worked example with the values above

  1. Steady value: Ta + P/G = 290 + 100/5 = 310 K.
  2. Approach: 1 − exp(−Gt/C) = 1 − exp(−1) = 0.63212.
  3. T = 300 + (10) × 0.63212 = 306.32 K.

Assumptions and limits

  • Constant properties, a uniform initial temperature and convection to a fixed ambient on both sides for the wall solutions.
  • For lumped models, a body with small internal temperature differences and constant conductances.

Common mistakes

  • Using the full thickness instead of the half-thickness in Bi and Fo.
  • Using the first-term form at small Fo, where more terms are needed.
  • Applying a lumped model when the Biot number is not small.

Statistics and uncertainty

First-term wall solutions are accurate to within about 2 % for Fo above 0.2, and lumped formulas need a small Biot number, below about 0.1, to stay within a few per cent.

Where it is used

  • Cooling and heating of slabs, plates and electronics enclosures.
  • Estimating warm-up and settling times.

Maths you need

  • Biot number: Bi = hL/k
  • Fourier number: Fo = αt/L²
  • Time constant: τ = C/G, capacitance over conductance

Related formulas