Equilibration time constant of two finite bodies

Time constant for two lumped bodies of heat capacity C1 and C2, isolated from their surroundings, to exchange heat through a conductance G.

Ref
HTS-24
Rev
v1
Field
Heat transfer and thermal systems
Result
τ [s]

Two lumped bodies with capacitances C1 and C2 joined by a conductance G and isolated from the surroundings equalise their temperatures exponentially. The difference decays with the time constant τ = C₁C₂/[G(C₁ + C₂)]. It is the series combination of the two capacitances divided by G, and is shorter than the single-body time constant of either body.

Time constant for two lumped bodies of heat capacity C1 and C2, isolated from their surroundings, to exchange heat through a conductance G. Their temperature difference falls by a factor e in time τ.

Calculator

Solve for
s
J/K
11,000,000
J/K
11,000,000
W/K
0.011,000
  • Series capacitance, C₁C₂/(C₁ + C₂)120 J/K
  • Time to equalise within 1 %, 4.605τ138.2 s
  • Weight of body 1 in the final temperature, C₁/(C₁ + C₂)0.4

What drives the result

Each variable is moved across its typical range while the others stay at the values above. The longest bar is the key driver.

Time constant (s) current value 30 s
GConductance between the bodiesKey driver
0.1212,000
C1Capacitance of body 1
0.24975
C2Capacitance of body 2
0.24950
  • The temperature difference between the bodies falls by a factor of e every 30 s and is within 1 % after 138.2 s.
  • The final common temperature is the capacitance-weighted average, with 40 % weight on body 1.
Chart data as tables

Ranked variables

VariableTypical rangeLowest resultHighest resultSwing (s)Local stepChange in result
G Conductance between the bodies0.01 to 1,000 W/K0.1212,00012,000+10%−9.09 %
C1 Capacitance of body 11 to 1,000,000 J/K0.249274.9874.73+10%+5.77 %
C2 Capacitance of body 21 to 1,000,000 J/K0.248849.9949.74+10%+3.77 %

Sweep of Conductance between the bodies

Conductance between the bodies (W/K)Time constant (s)
0.0112,000
0.042172,846
0.1778674.8
0.7499160
3.16237.95
13.348.999
56.232.134
237.10.506
1,0000.12

Sweep one variable

Time constant (s)Hover, touch, or use the arrow keys on the chart
0200040006000800010k12k 0.010.11101001000 Conductance between the bodies (W/K), log scale now 30

Variables and how each one contributes

τ

Time constant

Result · s

What the equation gives you. Everything else feeds it.

C1

Capacitance of body 1

J/K · typical 1 to 1,000,000

The thermal capacitance of body 1, in J/K. A larger capacitance slows equilibration. Raising it by 10 % (to 220) moves the result by +5.77 %, from 30 to 31.73 s.

C2

Capacitance of body 2

J/K · typical 1 to 1,000,000

The thermal capacitance of body 2, in J/K. A larger capacitance slows equilibration. Raising it by 10 % (to 330) moves the result by +3.77 %, from 30 to 31.13 s.

G

Conductance between the bodies

W/K · typical 0.01 to 1,000

The conductance between the bodies, in W/K. A larger conductance shortens the time constant in inverse proportion. Raising it by 10 % (to 4.4) moves the result by −9.09 %, from 30 to 27.27 s.

Worked example with the values above

  1. Product: C₁C₂ = 200 × 300 = 60,000 J²/K²; sum: C₁ + C₂ = 500 J/K.
  2. Series capacitance: 120 J/K.
  3. τ = 120 / 4 = 30 s.

Assumptions and limits

  • Constant properties, a uniform initial temperature and convection to a fixed ambient on both sides for the wall solutions.
  • For lumped models, a body with small internal temperature differences and constant conductances.

Common mistakes

  • Using the full thickness instead of the half-thickness in Bi and Fo.
  • Using the first-term form at small Fo, where more terms are needed.
  • Applying a lumped model when the Biot number is not small.

Statistics and uncertainty

First-term wall solutions are accurate to within about 2 % for Fo above 0.2, and lumped formulas need a small Biot number, below about 0.1, to stay within a few per cent.

Where it is used

  • Cooling and heating of slabs, plates and electronics enclosures.
  • Estimating warm-up and settling times.

Maths you need

  • Biot number: Bi = hL/k
  • Fourier number: Fo = αt/L²
  • Time constant: τ = C/G, capacitance over conductance