Your Equation

Library / Aerospace / AER-37

Aerospace

Velocity gradient in a varying-area duct

Rate of change of speed along a smooth duct in steady quasi-one-dimensional isentropic flow with no mass addition, from the local area slope.

Ref
AER-37
Rev
v1
Field
Aerospace
Result
dV/dx [1/s]

Mass, momentum and energy conservation in quasi-one-dimensional isentropic flow give the area–velocity relation dV/V = [1/(M² − 1)] dA/A, which means dV/dx = [V/(M² − 1)](1/A)(dA/dx). In subsonic flow (M < 1) the speed rises as the area falls, and in supersonic flow it rises as the area increases, so a nozzle converges, then diverges. The expression is singular at M = 1, where the area is a minimum.

Rate of change of speed along a smooth duct in steady quasi-one-dimensional isentropic flow with no mass addition, from the local area slope. Subsonic flow speeds up in a converging duct; supersonic flow speeds up in a diverging one. The form is singular at M = 1.

Calculator

Solve for
1/s
m/s
501,500
m²/m
−0.10.1
m²
0.011
0.26
  • Relative area slope, (1/A)dA/dx0.2 1/m
  • Factor 1/(M² − 1)0.3333
  • Speed change over 1 m of duct, V(dA/dx)/(A(M² − 1)) × 1 m40 m/s

What drives the result

Each variable is moved across its typical range while the others stay at the values above. The longest bar is the key driver.

Velocity gradient (1/s) current value 40 1/s
MMach numberKey driver
−2,280332
dA/dxArea gradient
−200200
ALocal area
4400
VFlow speed
3.33100
  • The flow speeds up by 40 m/s for each metre of duct, a relative change of 6.67 % per metre.
  • The flow is supersonic, so widening the duct (positive area slope) accelerates it; the reverse is true below Mach 1.
Chart data as tables

Ranked variables

VariableTypical rangeLowest resultHighest resultSwing (1/s)Local stepChange in result
M Mach number0.2 to 6 −2,280332.32,613+10%−21.9 %
dA/dx Area gradient−0.1 to 0.1 m²/m−200200400+0.01 m²/m+50 %
A Local area0.01 to 1 m²4400396+10%−9.09 %
V Flow speed50 to 1,500 m/s3.33310096.67+10%+10 %

Sweep of Mach number

Mach numberVelocity gradient (1/s)
0.2−125
0.925−831.2
1.6569.67
2.37525.86
3.113.94
3.8258.804
4.556.091
5.2754.473
63.429

Sweep one variable

Velocity gradient (1/s)Hover, touch, or use the arrow keys on the chart
−25k−20k−15k−10k−50000 123456 Mach number now 40

Variables and how each one contributes

dV/dx

Velocity gradient

Result · 1/s

What the equation gives you. Everything else feeds it.

V

Flow speed

m/s · typical 50 to 1,500

The local flow speed, in m/s. Scales the gradient in direct proportion. Raising it by 10 % (to 660) moves the result by +10 %, from 40 to 44 1/s.

dA/dx

Area gradient

m²/m · typical −0.1 to 0.1

The local area slope dA/dx, in m²/m. A faster-widening duct gives a larger acceleration (supersonic) or deceleration (subsonic). Raising it by 10 % (to 0.022) moves the result by +10 %, from 40 to 44 1/s.

A

Local area

m² · typical 0.01 to 1

The local duct area, in m². A larger area lowers the relative area change and so the gradient. Raising it by 10 % (to 0.11) moves the result by −9.09 %, from 40 to 36.36 1/s.

M

Mach number

· typical 0.2 to 6

The local Mach number, away from 1. The gradient is largest near Mach 1, and changes sign across it. Raising it by 10 % (to 2.2) moves the result by −21.9 %, from 40 to 31.25 1/s.

Worked example with the values above

  1. Relative area slope: (1/A)dA/dx = 0.02 / 0.1 = 0.2 1/m.
  2. Mach factor: M² − 1 = 4 − 1 = 3.
  3. dV/dx = 600 × 0.2 / 3 = 40 1/s.

Assumptions and limits

  • Steady, adiabatic, reversible flow of a calorically perfect gas, with no shocks or friction.
  • A constant heat-capacity ratio, and quasi-one-dimensional flow where an area enters.

Common mistakes

  • Using the formula at M = 1, where it is singular and the flow is choked.
  • Using the wrong sign for the area slope in a converging section.
  • Applying it to flows with friction, heat addition or shocks.

Statistics and uncertainty

Isentropic relations are exact for a perfect gas. Real nozzle flow departs from them: boundary layers and non-equilibrium chemistry make mass flow a few per cent lower, and for hot combustion gas γ is a function of temperature, not a constant.

Where it is used

  • Sizing nozzles, inlets and diffusers.
  • Referring engine data to standard conditions for comparison.

Maths you need

  • Stagnation conditions: the state reached if the flow is slowed to rest isentropically
  • Choking: the flow is sonic at the minimum area and the mass flow is maximal
  • Mach number: M = V/a

Related formulas

Practise this formula