Your Equation

Library / Aerospace / AER-51

Aerospace

Turbine total pressure ratio from actual temperature drop

Outlet-to-inlet total pressure ratio of a turbine from its measured total temperature drop and total-to-total isentropic efficiency ηt.

Ref
AER-51
Rev
v1
Field
Aerospace
Result
pt5/pt4

A turbine’s actual temperature drop is related to the ideal one by its isentropic efficiency: Tt4 − Tt5 = ηt Tt4[1 − (pt5/pt4)^((γ−1)/γ)]. Solving gives the pressure ratio pt5/pt4 = [1 − (Tt4 − Tt5)/(ηt Tt4)]^(γ/(γ−1)). It is below 1, since the gas expands. The bracket is the ideal exit-to-inlet temperature ratio and it must be positive.

Outlet-to-inlet total pressure ratio of a turbine from its measured total temperature drop and total-to-total isentropic efficiency ηt. The bracket is the ideal outlet-to-inlet temperature ratio and must be positive. The page needs T4 ≥ T5.

Calculator

Solve for
K
1,0002,000
K
6001,200
0.70.95
1.11.67
  • Ideal temperature ratio, bracket0.75
  • Actual temperature ratio, Tt5/Tt40.8
  • Expansion ratio, pt4/pt52.737

What drives the result

Each variable is moved across its typical range while the others stay at the values above. The longest bar is the key driver.

Turbine pressure ratio () current value 0.3654
Tt5Outlet total temperatureKey driver
0.03231
Tt4Inlet total temperature
0.02540.836
γHeat-capacity ratio
0.04220.488
ηtIsentropic efficiency
0.3080.437
  • The turbine expands the gas by a factor of 2.737 in total pressure, so the outlet pressure is 36.54 % of the inlet value.
  • If the turbine were ideal (ηt = 1) the same temperature drop would need only an expansion ratio of 2.184, so the inefficiency costs 0.553 in expansion ratio.
Chart data as tables

Ranked variables

VariableTypical rangeLowest resultHighest resultSwing ()Local stepChange in result
Tt5 Outlet total temperature600 to 1,200 K0.0322910.9677+10%+55 %
Tt4 Inlet total temperature1,000 to 2,000 K0.025370.83570.8103+10%−36.4 %
γ Heat-capacity ratio1.1 to 1.67 0.042240.48820.446+10%+20.5 %
ηt Isentropic efficiency0.7 to 0.95 0.3080.43720.1292+10%+11 %

Sweep of Isentropic efficiency

Isentropic efficiencyTurbine pressure ratio
0.70.308
0.73120.3268
0.76250.3448
0.79370.362
0.8250.3784
0.85620.3941
0.88750.4091
0.91870.4235
0.950.4372

Sweep one variable

Turbine pressure ratio ()Hover, touch, or use the arrow keys on the chart
0.30.320.340.360.380.40.420.44 0.70.750.80.850.90.95 Isentropic efficiency now 0.3654

Variables and how each one contributes

pt5/pt4

Turbine pressure ratio

Result ·

What the equation gives you. Everything else feeds it.

Tt4

Inlet total temperature

K · typical 1,000 to 2,000

The inlet total temperature, in K. For a fixed temperature drop, hotter gas has a smaller relative drop and so a milder expansion ratio. Raising it by 10 % (to 1,320) moves the result by −36.4 %, from 0.3654 to 0.2324.

Tt5

Outlet total temperature

K · typical 600 to 1,200

The outlet total temperature, in K. A cooler outlet means more work taken and a lower pressure ratio. Raising it by 10 % (to 1,056) moves the result by +55 %, from 0.3654 to 0.5662.

ηt

Isentropic efficiency

· typical 0.7 to 0.95

The total-to-total isentropic efficiency. A lower efficiency needs a larger expansion for the same temperature drop, lowering the pressure ratio. Raising it by 10 % (to 0.88) moves the result by +11 %, from 0.3654 to 0.4056.

γ

Heat-capacity ratio

· typical 1.1 to 1.67

The heat-capacity ratio cp/cv of the gas, about 1.4 for air. A lower γ (hotter, more complex gas) changes the compressible-flow exponents and the sizes of the shock and expansion effects. Raising it by 10 % (to 1.54) moves the result by +20.5 %, from 0.3654 to 0.4402.

Worked example with the values above

  1. Actual drop: Tt4 − Tt5 = 1,200 − 960 = 240 K.
  2. Bracket: 1 − 240 / (0.8 × 1,200) = 0.75.
  3. pt5/pt4 = 0.75^3.5 = 0.365354.

Assumptions and limits

  • Constant specific heats in each stream, adiabatic components and total-to-total efficiencies.
  • Steady operation at one operating point, with no bleed and no leakage unless the page says so.

Common mistakes

  • Mixing total and static states.
  • Using a total-to-static efficiency where a total-to-total one is needed.
  • Forgetting the fuel added to the turbine mass flow.

Statistics and uncertainty

Constant-cp cycle calculations are rough: cp rises from 1005 J/(kg·K) in cold air to about 1150 J/(kg·K) in hot gas, which shifts results by 5 % to 10 %. Component efficiencies from maps are good to 1 % to 2 % at design and worse off design.

Where it is used

  • Matching compressors, combustors and turbines and finding fuel flow and power.
  • Sizing engines and checking cycle designs.

Maths you need

  • Isentropic efficiency: ideal work divided by actual work (or the reverse for a turbine)
  • Total temperature: the temperature the gas would reach at rest
  • Brayton cycle: compression, heat addition, expansion

Related formulas

Practise this formula