Library / Aerospace / AER-50
Aerospace
Turbine exit temperature from shaft-power balance
Total temperature leaving a turbine that must supply shaft power Pload, including the connected compressor and accessory demand.
- Ref
- AER-50
- Rev
- v1
- Field
- Aerospace
- Result
- Tt5 [K]
A turbine delivering shaft power P must extract it from the gas. An energy balance gives ηm ṁg cpg (Tt4 − Tt5) = P, so Tt5 = Tt4 − P/(ηm ṁg cpg). The gas flow ṁg includes the fuel added and excludes the bleed taken off. The mechanical efficiency ηm covers bearing and gearbox losses. Check that the exit temperature is above zero and physically sensible.
Total temperature leaving a turbine that must supply shaft power Pload, including the connected compressor and accessory demand. mg is the actual turbine gas flow after fuel addition and bleed, ηm the mechanical efficiency, and cp is constant. Check that the exit temperature is physically feasible and positive.
Calculator
- Temperature drop, Tt4 − Tt5177.5 K
- Gas power extracted, ṁg cp ΔT2,041,000 W
- Exit-to-inlet temperature ratio0.8732
What drives the result
Each variable is moved across its typical range while the others stay at the values above. The longest bar is the key driver.
- The turbine takes the gas from 1,400 K to 1,222.5 K, a drop of 177.5 K, to deliver 2,000 kW.
- The exit is 87.32 % of the inlet temperature on an absolute scale; the same power from half the gas flow would need twice the temperature drop.
Chart data as tables
Ranked variables
| Variable | Typical range | Lowest result | Highest result | Swing (K) | Local step | Change in result |
|---|---|---|---|---|---|---|
| Tt4 Turbine inlet total temperature | 900 to 2,000 K | 722.5 | 1,823 | 1,100 | +10% | +11.5 % |
| Pload Required shaft power | 100,000 to 1e7 W | 512.7 | 1,391 | 878.4 | +10% | −1.45 % |
| ṁg Turbine gas mass flow | 2 to 100 kg/s | 512.7 | 1,382 | 869.6 | +10% | +1.32 % |
| cp,g Specific heat of the gas | 1,000 to 1,300 J/(kg·K) | 1,196 | 1,243 | 47.1 | +10% | +1.32 % |
| ηm Mechanical efficiency | 0.9 to 1 | 1,207 | 1,226 | 19.32 | +10% | +1.32 % |
Sweep of Required shaft power
| Required shaft power (W) | Turbine exit total temperature (K) |
|---|---|
| 100,000 | 1,391 |
| 1,338,000 | 1,281 |
| 2,575,000 | 1,172 |
| 3,813,000 | 1,062 |
| 5,050,000 | 951.9 |
| 6,288,000 | 842.1 |
| 7,525,000 | 732.3 |
| 8,763,000 | 622.5 |
| 1e7 | 512.7 |
Sweep one variable
Variables and how each one contributes
Turbine exit total temperature
What the equation gives you. Everything else feeds it.
Turbine inlet total temperature
The turbine inlet total temperature, in K. Raises the exit temperature one-for-one. Raising it by 10 % (to 1,540) moves the result by +11.5 %, from 1,223 to 1,363 K.
Required shaft power
The required shaft power, including the compressor and accessory demand, in W. Lowers the exit temperature in direct proportion to P. Raising it by 10 % (to 2,200,000) moves the result by −1.45 %, from 1,223 to 1,205 K.
Mechanical efficiency
The mechanical efficiency. A lower efficiency means more gas power is needed, lowering the exit temperature. Raising it by 10 % (to 1.078) moves the result by +1.32 %, from 1,223 to 1,239 K.
Turbine gas mass flow
The actual gas mass flow through the turbine, in kg/s. A larger flow spreads the work, so a smaller temperature drop. Raising it by 10 % (to 11) moves the result by +1.32 %, from 1,223 to 1,239 K.
Specific heat of the gas
The specific heat of the gas, in J/(kg·K). A larger specific heat gives a smaller temperature drop for the same power. Raising it by 10 % (to 1,265) moves the result by +1.32 %, from 1,223 to 1,239 K.
Worked example with the values above
- Gas power needed: P/ηm = 2,000,000 / 0.98 = 2,040,816 W.
- Temperature drop: 2,040,816 / (10 × 1,150) = 177.462 K.
- Tt5 = 1,400 − 177.462 = 1,222.54 K.
Assumptions and limits
- Constant specific heats in each stream, adiabatic components and total-to-total efficiencies.
- Steady operation at one operating point, with no bleed and no leakage unless the page says so.
Common mistakes
- Mixing total and static states.
- Using a total-to-static efficiency where a total-to-total one is needed.
- Forgetting the fuel added to the turbine mass flow.
Statistics and uncertainty
Constant-cp cycle calculations are rough: cp rises from 1005 J/(kg·K) in cold air to about 1150 J/(kg·K) in hot gas, which shifts results by 5 % to 10 %. Component efficiencies from maps are good to 1 % to 2 % at design and worse off design.
Where it is used
- Matching compressors, combustors and turbines and finding fuel flow and power.
- Sizing engines and checking cycle designs.
Maths you need
- Isentropic efficiency: ideal work divided by actual work (or the reverse for a turbine)
- Total temperature: the temperature the gas would reach at rest
- Brayton cycle: compression, heat addition, expansion