Reverse view factor from reciprocity

View factor from surface 2 to surface 1, from the areas A1 and A2 and the known view factor F12 between diffuse surfaces.

Ref
HTS-34
Rev
v1
Field
Heat transfer and thermal systems
Result
F21

The reciprocity relation for view factors between diffuse surfaces is A₁F₁₂ = A₂F₂₁, so F₂₁ = (A₁/A₂)F₁₂. It lets you find one view factor from the other and the two areas. Both factors must lie between 0 and 1; a result above one signals inconsistent areas or an inconsistent view factor.

View factor from surface 2 to surface 1, from the areas A1 and A2 and the known view factor F12 between diffuse surfaces. A result above one flags inconsistent geometry or input.

Calculator

Solve for
m²
0.0110
m²
0.0110
01
  • Exchange area, A₁F₁₂ = A₂F₂₁0.15 m²
  • Margin below one, 1 − F₂₁0.7
  • Area ratio, A₁/A₂0.4

What drives the result

Each variable is moved across its typical range while the others stay at the values above. The longest bar is the key driver.

View factor from 2 to 1 () current value 0.3
A1Area of surface 1Key driver
0.01515
A2Area of surface 2
0.01515
F12View factor from 1 to 2
00.4
  • Of the radiation leaving surface 2, 30 % reaches surface 1, compared with 75 % in the other direction.
  • The exchange area A₁F₁₂ = 0.15 m² is the same from either side, which is why the smaller surface sees a larger fraction of the larger one.
Chart data as tables

Ranked variables

VariableTypical rangeLowest resultHighest resultSwing ()Local stepChange in result
A1 Area of surface 10.01 to 10 m²0.0151514.98+10%+10 %
A2 Area of surface 20.01 to 10 m²0.0151514.98+10%−9.09 %
F12 View factor from 1 to 20 to 1 00.40.4+10%+10 %

Sweep of View factor from 1 to 2

View factor from 1 to 2View factor from 2 to 1
00
0.1250.05
0.250.1
0.3750.15
0.50.2
0.6250.25
0.750.3
0.8750.35
10.4

Sweep one variable

View factor from 2 to 1 ()Hover, touch, or use the arrow keys on the chart
00.10.20.30.4 00.20.40.60.81 View factor from 1 to 2 now 0.3

Variables and how each one contributes

F21

View factor from 2 to 1

Result ·

What the equation gives you. Everything else feeds it.

A1

Area of surface 1

m² · typical 0.01 to 10

The area of surface 1, in m². Raises F₂₁ in direct proportion. Raising it by 10 % (to 0.22) moves the result by +10 %, from 0.3 to 0.33.

A2

Area of surface 2

m² · typical 0.01 to 10

The area of surface 2, in m². Lowers F₂₁ in inverse proportion. Raising it by 10 % (to 0.55) moves the result by −9.09 %, from 0.3 to 0.2727.

F12

View factor from 1 to 2

· typical 0 to 1

The view factor from surface 1 to surface 2. Raises F₂₁ in direct proportion. Raising it by 10 % (to 0.825) moves the result by +10 %, from 0.3 to 0.33.

Worked example with the values above

  1. Area ratio: A₁/A₂ = 0.2 / 0.5 = 0.4.
  2. Multiply by F₁₂ = 0.75.
  3. F₂₁ = 0.3.

Assumptions and limits

  • Opaque, diffuse and grey surfaces, isothermal with uniform properties.
  • A transparent, non-participating gap, and absolute temperatures in kelvin.

Common mistakes

  • Using °C in the fourth-power terms.
  • Using the plate formula when the surfaces are not large compared with the gap.
  • Forgetting that an emissivity of 1 means a perfect black surface and 0 a perfect reflector.

Statistics and uncertainty

Emissivity values are uncertain by 10 % to 30 % for real surfaces, and temperature errors are multiplied by four in the fourth-power law, so a 2 % error in absolute temperature gives roughly 8 % in flux.

Where it is used

  • Furnaces, cryostats, ovens and spacecraft thermal design.
  • Choosing shield layers and estimating radiant exposure.

Maths you need

  • Stefan–Boltzmann law: E = σT⁴, with σ = 5.670×10⁻⁸ W/(m² K⁴)
  • Emissivity: ε, the ratio of emission to that of a blackbody
  • View factor: the fraction of radiation leaving one surface that reaches another