Pipe friction and fitting losses

Head lost to straight-pipe friction and fittings in a pipe run.

Ref
FLU-04
Rev
v1
Field
Fluid Mechanics
Result
hL [m]

The Darcy friction factor fD is four times the Fanning factor. Use the mean speed specified for each fitting. Add the straight-pipe and fitting losses. The calculator gives total head loss and the pressure drop for water.

Water loses energy to rubbing along the pipe wall and to bends and valves; both losses grow with the square of the speed.

Calculator

Solve for
m
0.0080.1
m
11,000
mm
10500
m/s
0.110
020
  • Friction loss hf0.8158 m
  • Pressure drop for water8 kPa

What drives the result

Each variable is moved across its typical range while the others stay at the values above. The longest bar is the key driver.

Total head loss (m) current value 0.8158 m
LPipe lengthKey driver
0.081681.6
VMean speed
0.0020420.4
ΣKFitting loss coefficients
4.89
DPipe diameter
0.08164.08
fDDarcy friction factor
0.3264.08
  • Water at 2 m/s in 10 m of 50 mm pipe loses about 0.82 m of head, an 8 kPa pressure drop.
  • Halving the diameter at the same flow rate raises the speed fourfold and the loss by about 32 times.
Chart data as tables

Ranked variables

VariableTypical rangeLowest resultHighest resultSwing (m)Local stepChange in result
L Pipe length1 to 1,000 m0.0815881.5881.5+10%+10 %
V Mean speed0.1 to 10 m/s0.00203920.3920.39+10%+21 %
ΣK Fitting loss coefficients0 to 20 0.81584.8954.079+10%0 %
D Pipe diameter10 to 500 mm0.081584.0793.997+10%−9.09 %
fD Darcy friction factor0.008 to 0.1 0.32634.0793.753+10%+10 %

Sweep of Mean speed

Mean speed (m/s)Total head loss (m)
0.10.002039
0.17780.006449
0.31620.02039
0.56230.06449
10.2039
1.7780.6449
3.1622.039
5.6236.449
1020.39

Sweep one variable

Total head loss (m)Hover, touch, or use the arrow keys on the chart
05101520 0.10.20.512510 Mean speed (m/s), log scale now 0.8158

Variables and how each one contributes

hL

Total head loss

Result · m

What the equation gives you. Everything else feeds it.

fD

Darcy friction factor

· typical 0.008 to 0.1

Darcy friction factor. Directly proportional to friction loss.

L

Pipe length

m · typical 1 to 1,000

Straight pipe length. Directly proportional to friction loss.

D

Pipe diameter

mm · typical 10 to 500

Internal diameter. A wider pipe cuts friction loss sharply.

V

Mean speed

m/s · typical 0.1 to 10

Mean flow speed. Squared: the strongest driver.

ΣK

Fitting loss coefficients

· typical 0 to 20

Sum of fitting loss coefficients (elbows, valves, entries). Adds K V²/2g.

Worked example with the values above

  1. Velocity head: V²/2g = 2² / 19.61 = 0.2039 m.
  2. Loss coefficient: fDL/D + ΣK = 0.02 × 200 + 0 = 4.
  3. hL = 0.8158 m (about 8 kPa for water).

Assumptions and limits

  • Fully developed flow in a round pipe.
  • Constant friction factor.

Common mistakes

  • Using Fanning in place of Darcy.
  • Using the wrong diameter units.

Statistics and uncertainty

Friction factors from roughness charts are uncertain by ±10–20%, which carries straight into the loss.

Where it is used

  • Pump and piping-system design.
  • Water-cooling and fuel-line checks.

Maths you need

  • Reynolds number: Re = ρVD/μ
  • Velocity head: V²/2g

Related formulas