Hottest location in a slab with unequal face temperatures

Position of the temperature maximum in a heated slab with different face temperatures Tl and Tr, measured from the left face.

Ref
HTS-09
Rev
v1
Field
Heat transfer and thermal systems
Result
xmax [m]

With unequal face temperatures Tl and Tr and uniform heating, the temperature is a parabola whose peak is at xmax = L/2 + k(Tr − Tl)/(q‴L), measured from the left face. The hotter face pulls the peak towards itself. If this stationary point falls outside the slab, the maximum is at the hotter face, so the result is clipped to the range 0 to L.

Position of the temperature maximum in a heated slab with different face temperatures Tl and Tr, measured from the left face. If the stationary point falls outside the slab, the hotter face is the maximum.

Calculator

Solve for
m
m
0.0011
W/(m K)
0.1500
K
2501,000
K
2501,000
W/m³
1,0001e9
  • Unclipped stationary position0.07 m
  • Offset of the peak from the centre0.02 m
  • Heat generated per unit area, q‴L10,000 W/m²

What drives the result

Each variable is moved across its typical range while the others stay at the values above. The longest bar is the key driver.

Position of maximum temperature (m) current value 0.07 m
LSlab thicknessKey driver
0.0010.502
TlLeft-face temperature
00.1
TrRight-face temperature
00.1
q‴Volumetric heat generation
0.050.1
kThermal conductivity
0.05020.1
  • The temperature peaks 0.07 m from the left face, 0.02 m to the right of the centre, towards the hotter face.
  • A result of exactly 0 or 0.1 m would mean the maximum sits on a face, which happens when the face temperature difference outweighs the internal heating.
Chart data as tables

Ranked variables

VariableTypical rangeLowest resultHighest resultSwing (m)Local stepChange in result
L Slab thickness0.001 to 1 m0.0010.5020.501+10%+4.55 %
Tl Left-face temperature250 to 1,000 K00.10.1+10%−42.9 %
Tr Right-face temperature250 to 1,000 K00.10.1+10%+42.9 %
q‴ Volumetric heat generation1,000 to 1e9 W/m³0.050.10.05+10%−2.6 %
k Thermal conductivity0.1 to 500 W/(m K)0.05020.10.0498+10%+2.86 %

Sweep of Right-face temperature

Right-face temperature (K)Position of maximum temperature (m)
2500
343.80.09375
437.50.1
531.30.1
6250.1
718.80.1
812.50.1
906.30.1
1,0000.1

Sweep one variable

Position of maximum temperature (m)Hover, touch, or use the arrow keys on the chart
00.020.040.060.080.1 300500700900 Right-face temperature (K) now 0.07

Variables and how each one contributes

xmax

Position of maximum temperature

Result · m

What the equation gives you. Everything else feeds it.

L

Slab thickness

m · typical 0.001 to 1

The full slab thickness, in m. A thicker slab reduces the shift of the peak from the centre, so the position moves nearer L/2. Raising it by 10 % (to 0.11) moves the result by +4.55 %, from 0.07 to 0.07318 m.

k

Thermal conductivity

W/(m K) · typical 0.1 to 500

The thermal conductivity, in W/(m K). A higher conductivity makes the face temperatures matter more, shifting the peak further from the centre. Raising it by 10 % (to 11) moves the result by +2.86 %, from 0.07 to 0.072 m.

Tl

Left-face temperature

K · typical 250 to 1,000

The left-face temperature, in K. A hotter left face moves the peak towards the left. Raising it by 10 % (to 330) moves the result by −42.9 %, from 0.07 to 0.04 m.

Tr

Right-face temperature

K · typical 250 to 1,000

The right-face temperature, in K. A hotter right face moves the peak towards the right. Raising it by 10 % (to 352) moves the result by +42.9 %, from 0.07 to 0.1 m.

q‴

Volumetric heat generation

W/m³ · typical 1,000 to 1e9

The uniform volumetric heat generation, in W/m³. More heating moves the peak back towards the centre. Raising it by 10 % (to 110,000) moves the result by −2.6 %, from 0.07 to 0.06818 m.

Worked example with the values above

  1. Shift from the centre: k(Tr − Tl)/(q‴L) = 10 × 20 / (100,000 × 0.1) = 0.02 m.
  2. Unclipped position: L/2 + shift = 0.05 + 0.02 = 0.07 m.
  3. Clip to 0 … 0.1: xmax = 0.07 m.

Assumptions and limits

  • Uniform volumetric generation and constant conductivity in a steady state.
  • The stated boundary condition holds exactly, for example a fixed surface temperature or an insulated inner surface.

Common mistakes

  • Mixing the factor 2, 4 or 6 between the slab, cylinder and sphere.
  • Using the half-thickness or the full thickness in the wrong place.
  • Forgetting that generation is per unit volume, not per unit area.

Statistics and uncertainty

Volumetric heating is often known only to 10 % to 20 %, and the peak temperature scales directly with it. Use a margin on predicted centreline or hot-spot temperatures.

Where it is used

  • Hot-spot checks in busbars, fuel rods, heated plates and spherical particles.
  • Finding the surface temperature a coolant must hold for a given peak.

Maths you need

  • Volumetric generation: q‴ in W/m³
  • Steady conduction equation: k∇²T + q‴ = 0
  • Symmetry: zero gradient at the centre