Entropy generation in an insulated heat exchanger

Rate of entropy generation in a heat exchanger with no heat leakage or pressure drop, from the heat-capacity rates and the inlet and outlet temperatures of the two single-phase streams.

Ref
HTS-48
Rev
v1
Field
Heat transfer and thermal systems
Result
Ṡgen [W/K]

The entropy generation rate of an insulated heat exchanger with constant heat-capacity rates is Ṡgen = Ch ln(Th,out/Th,in) + Cc ln(Tc,out/Tc,in). The hot stream contributes a negative term and the cold stream a positive one; the sum must be non-negative. A negative result means the data break the second law. First check that the hot-side heat loss equals the cold-side gain.

Rate of entropy generation in a heat exchanger with no heat leakage or pressure drop, from the heat-capacity rates and the inlet and outlet temperatures of the two single-phase streams. It must be non-negative for a physically possible exchanger.

Calculator

Solve for
W/K
W/K
1100,000
K
2501,000
K
2501,000
W/K
1100,000
K
2501,000
K
2501,000
  • Heat released by the hot stream, Ch(Thi − Tho)10,000 W
  • Heat gained by the cold stream, Cc(Tco − Tci)10,000 W
  • Energy-balance mismatch, hot minus cold0 W

What drives the result

Each variable is moved across its typical range while the others stay at the values above. The longest bar is the key driver.

Entropy generation rate (W/K) current value 4.124 W/K
CcHeat-capacity rate of the cold streamKey driver
−26.615,400
ChHeat-capacity rate of the hot stream
−13,30030.7
Th,inHot-stream inlet temperature
−17998.1
Tc,outCold-stream outlet temperature
−63.2214
Th,outHot-stream outlet temperature
−63.2214
Tc,inCold-stream inlet temperature
−23740.6
  • The exchanger generates 4.124 W/K of entropy; this is physically allowed.
  • The hot stream gives 10,000 W and the cold stream takes 10,000 W, a mismatch of 0 W; the formula assumes these are equal.
Chart data as tables

Ranked variables

VariableTypical rangeLowest resultHighest resultSwing (W/K)Local stepChange in result
Cc Heat-capacity rate of the cold stream1 to 100,000 W/K−26.5515,39015,410+10%+74.8 %
Ch Heat-capacity rate of the hot stream1 to 100,000 W/K−13,32030.713,350+10%−64.8 %
Th,in Hot-stream inlet temperature250 to 1,000 K−179.198.12277.3+10%−462 %
Tc,out Cold-stream outlet temperature250 to 1,000 K−63.17214.1277.3+10%+462 %
Th,out Hot-stream outlet temperature250 to 1,000 K−63.17214.1277.3+10%+462 %
Tc,in Cold-stream inlet temperature250 to 1,000 K−236.740.59277.3+10%−462 %

Sweep of Hot-stream outlet temperature

Hot-stream outlet temperature (K)Entropy generation rate (W/K)
250−63.17
343.80.5202
437.548.75
531.387.58
625120.1
718.8148
812.5172.6
906.3194.4
1,000214.1

Sweep one variable

Entropy generation rate (W/K)Hover, touch, or use the arrow keys on the chart
−50050100150200 300500700900 Hot-stream outlet temperature (K) now 4.124

Variables and how each one contributes

Ṡgen

Entropy generation rate

Result · W/K

What the equation gives you. Everything else feeds it.

Ch

Heat-capacity rate of the hot stream

W/K · typical 1 to 100,000

The heat-capacity rate of the hot stream, in W/K. Scales the hot-stream term, which is negative as the stream cools. Raising it by 10 % (to 220) moves the result by −64.8 %, from 4.124 to 1.453 W/K.

Th,in

Hot-stream inlet temperature

K · typical 250 to 1,000

The hot-stream inlet temperature, in K. A hotter inlet makes the hot stream’s entropy drop larger in magnitude. Raising it by 10 % (to 440) moves the result by −462 %, from 4.124 to −14.94 W/K.

Th,out

Hot-stream outlet temperature

K · typical 250 to 1,000

The hot-stream outlet temperature, in K. A hotter outlet lessens the hot stream’s entropy drop, raising the result. Raising it by 10 % (to 385) moves the result by +462 %, from 4.124 to 23.19 W/K.

Cc

Heat-capacity rate of the cold stream

W/K · typical 1 to 100,000

The heat-capacity rate of the cold stream, in W/K. Scales the cold-stream term, which is positive as the stream warms. Raising it by 10 % (to 220) moves the result by +74.8 %, from 4.124 to 7.207 W/K.

Tc,in

Cold-stream inlet temperature

K · typical 250 to 1,000

The cold-stream inlet temperature, in K. A warmer inlet lessens the cold stream’s entropy gain. Raising it by 10 % (to 330) moves the result by −462 %, from 4.124 to −14.94 W/K.

Tc,out

Cold-stream outlet temperature

K · typical 250 to 1,000

The cold-stream outlet temperature, in K. A warmer outlet raises the cold stream’s entropy gain, raising the result. Raising it by 10 % (to 385) moves the result by +462 %, from 4.124 to 23.19 W/K.

Worked example with the values above

  1. Hot stream: Ch ln(Tho/Thi) = 200 × ln(350/400) = −26.706 W/K.
  2. Cold stream: Cc ln(Tco/Tci) = 200 × ln(350/300) = 30.83 W/K.
  3. Ṡgen = 4.1239 W/K.

Assumptions and limits

  • Constant properties in each phase, a single melting temperature and no losses unless stated.
  • Steady or quasi-steady balances, with absolute temperatures where logarithms or powers are used.

Common mistakes

  • Forgetting the latent heat term, or counting it twice.
  • Using °C in an entropy or radiation formula.
  • Using these simple formulas when the Stefan number is not small.

Statistics and uncertainty

Latent heats and specific heats are tabulated to a few per cent, but real storage materials melt over a range and lose heat, so real systems typically deliver 5 % to 20 % less than the ideal values.

Where it is used

  • Sizing thermal storage, ice banks and phase-change units.
  • Checking exchanger data, mixing streams and cooling times.

Maths you need

  • Latent heat: energy per kilogram to change phase
  • Heat-capacity rate: C = ṁcp
  • Second law: entropy generation cannot be negative