Cumulative energy absorbed after a temperature step

Energy per unit area taken up by a semi-infinite solid up to time t after its surface steps to Ts.

Ref
HTS-18
Rev
v1
Field
Heat transfer and thermal systems
Result
E/A [J/m²]

The energy absorbed per unit area up to time t is the integral of the surface flux, E/A = 2k(Ts − Ti)√[t/(πα)]. It grows as √t, so quadrupling the time doubles the energy. The sign reverses for cooling, when Ts is below Ti, and the solid is assumed semi-infinite throughout.

Energy per unit area taken up by a semi-infinite solid up to time t after its surface steps to Ts. It is the time integral of the surface flux, so it grows as the square root of time.

Calculator

Solve for
J/m²
W/(m K)
0.1500
K
2501,000
K
2501,000
s
11,000,000
m²/s
1e-80.001
  • Mean flux over the interval, E/(At)11,280 W/m²
  • Energy after four times as long, 2E/A2,257,000 J/m²
  • Thermal penetration length, √(αt)0.01 m

What drives the result

Each variable is moved across its typical range while the others stay at the values above. The longest bar is the key driver.

Energy absorbed per unit area (J/m²) current value 1,128,000 J/m²
kThermal conductivityKey driver
56,4002.82e8
tTime since the step
113,0001.13e8
TsSurface temperature after the step
−1,130,0001.58e7
TiInitial temperature
−1.47e72,260,000
αThermal diffusivity
35,7001.13e7
  • After 100 s the solid has taken up 1,128,000 J per square metre, 1.128 MJ/m².
  • The heat goes into a layer about 0.01 m deep; four times the time would give 2,257,000 J/m², only double.
Chart data as tables

Ranked variables

VariableTypical rangeLowest resultHighest resultSwing (J/m²)Local stepChange in result
k Thermal conductivity0.1 to 500 W/(m K)56,4202.821e82.82e8+10%+10 %
t Time since the step1 to 1,000,000 s112,8001.128e81.127e8+10%+4.88 %
Ts Surface temperature after the step250 to 1,000 K−1,128,0001.58e71.693e7+10%+70 %
Ti Initial temperature250 to 1,000 K−1.467e72,257,0001.693e7+10%−60 %
α Thermal diffusivity1e-8 to 0.001 m²/s35,6801.128e71.125e7+10%−4.65 %

Sweep of Time since the step

Time since the step (s)Energy absorbed per unit area (J/m²)
1112,800
5.623267,600
31.62634,500
177.81,505,000
1,0003,568,000
5,6238,462,000
31,6202.007e7
177,8004.758e7
1,000,0001.128e8

Sweep one variable

Energy absorbed per unit area (J/m²)Hover, touch, or use the arrow keys on the chart
020M40M60M80M100M120M 110100100010k100k1M Time since the step (s), log scale now 1,128,000

Variables and how each one contributes

E/A

Energy absorbed per unit area

Result · J/m²

What the equation gives you. Everything else feeds it.

k

Thermal conductivity

W/(m K) · typical 0.1 to 500

The thermal conductivity, in W/(m K). Raises the absorbed energy in direct proportion. Raising it by 10 % (to 2.2) moves the result by +10 %, from 1,128,000 to 1,241,000 J/m².

Ts

Surface temperature after the step

K · typical 250 to 1,000

The surface temperature after the step, in K. Raises the energy in direct proportion to the temperature difference. Raising it by 10 % (to 385) moves the result by +70 %, from 1,128,000 to 1,918,000 J/m².

Ti

Initial temperature

K · typical 250 to 1,000

The initial temperature, in K. A higher initial temperature lowers the energy absorbed. Raising it by 10 % (to 330) moves the result by −60 %, from 1,128,000 to 451,400 J/m².

t

Time since the step

s · typical 1 to 1,000,000

The time since the step, in s. Raises the energy as the square root of time. Raising it by 10 % (to 110) moves the result by +4.88 %, from 1,128,000 to 1,183,000 J/m².

α

Thermal diffusivity

m²/s · typical 1e-8 to 0.001

The thermal diffusivity, in m²/s. A higher diffusivity lowers the energy for fixed k, as the heated layer is then thicker but warmer less deeply. Raising it by 10 % (to 1.1×10−6) moves the result by −4.65 %, from 1,128,000 to 1,076,000 J/m².

Worked example with the values above

  1. Time term: √(t/(πα)) = √(100 / (π × 1×10−6)) = 5,641.9 s/m.
  2. Factor 2k(Ts − Ti) = 2 × 2 × 50 = 200 W/m.
  3. E/A = 1,128,400 J/m².

Assumptions and limits

  • A semi-infinite solid with constant properties, so the back face is not felt over the time considered.
  • A one-dimensional geometry, an ideal step or constant flux at the surface and a uniform initial temperature.

Common mistakes

  • Using the formula after the thermal wave has reached the back face.
  • Using the step solution when the surface is heated by convection, which needs a different solution.
  • Entering time in minutes or hours when seconds are needed.

Statistics and uncertainty

Thermophysical properties of soils, concrete and foods vary by 10 % to 50 % with moisture and composition, so early-time results are only as good as the diffusivity and effusivity values.

Where it is used

  • Quenching, ground and wall heating, and contact burns.
  • Interpreting thin-film and heat-flux sensors.

Maths you need

  • Thermal diffusivity: α = k/(ρcp)
  • Complementary error function: erfc(x) = 1 − erf(x)
  • Thermal effusivity: e = √(kρcp)