Chemical

Stirred-tank reactor volume

Volume of a continuous stirred-tank reactor for a target conversion.

Ref
CHE-06
Rev
v1
Field
Chemical
Result
V [m³]

FA0 feed molar flow in mol/s, X conversion (0 to 1) and −rA the consumption rate in mol/(m³·s), evaluated at the exit conditions. Steady ideal stirred tank with one feed and one outlet.

A well-stirred tank behaves as if the whole contents are at the exit composition. The volume needed is the amount converted per second divided by how fast that exit mixture reacts.

Calculator

Solve for
m³
mol/s
0.1100
0.10.95
mol/(m³·s)
0.0110
  • Molar flow converted1.2 mol/s
  • Volume in litres3,000 L

What drives the result

Each variable is moved across its typical range while the others stay at the values above. The longest bar is the key driver.

Reactor volume (m³) current value 3 m³
FA0Feed molar flowKey driver
0.15150
−rAExit consumption rate
0.12120
XConversion
0.54.75
  • A stirred tank runs at the low exit rate throughout, so it is larger than a plug-flow reactor for the same conversion.
  • High conversion requires a large volume because the exit rate is low.
  • Several stirred tanks in series approach plug-flow performance.
Chart data as tables

Ranked variables

VariableTypical rangeLowest resultHighest resultSwing (m³)Local stepChange in result
FA0 Feed molar flow0.1 to 100 mol/s0.15150149.8+10%+10 %
−rA Exit consumption rate0.01 to 10 mol/(m³·s)0.12120119.9+10%−9.09 %
X Conversion0.1 to 0.95 0.54.754.25+undefined%—

Sweep of Conversion

ConversionReactor volume (m³)
0.10.5
0.20621.031
0.31251.563
0.41872.094
0.5252.625
0.63123.156
0.73753.687
0.84384.219
0.954.75

Sweep one variable

Reactor volume (m³)Hover, touch, or use the arrow keys on the chart
12345 0.10.30.50.70.9 Conversion now 3

Variables and how each one contributes

V

Reactor volume

Result · m³

What the equation gives you. Everything else feeds it.

FA0

Feed molar flow

mol/s · typical 0.1 to 100

Molar flow of reactant A into the reactor. Directly proportional.

X

Conversion

· typical 0.1 to 0.95

Fraction of A reacted. Strong: pushing conversion higher also lowers the rate, so volume rises faster than linearly if the rate falls.

−rA

Exit consumption rate

mol/(m³·s) · typical 0.01 to 10

Rate of consumption of A at the exit composition. Inversely proportional.

Worked example with the values above

  1. Moles converted per second: FA0X = 2 × 0.6 = 1.2 mol/s.
  2. Divide by the exit rate: 1.2 / 0.4.
  3. V = 3 m³.

Assumptions and limits

  • Steady, perfectly mixed tank, one feed and one outlet.
  • Rate evaluated at the exit composition and temperature.
  • Constant volumetric properties.

Common mistakes

  • Using the feed rate instead of the exit rate.
  • Entering conversion as a percentage.
  • Using it for a plug-flow reactor, which needs an integral.

Statistics and uncertainty

The rate constant behind −rA is typically uncertain by 10–20%, and the volume carries that uncertainty directly. Designers usually add a safety margin of 10–25% to the calculated volume.

Where it is used

  • Sizing reactors for fuel, propellant and decontamination processes.
  • Estimating residence time.
  • Comparing reactor types.

Maths you need

  • Conversion: fraction reacted
  • Reaction rate: mol per m³ per second

Related formulas

Practise this formula