Heat flow through a composite wall

Steady heat rate through a wall with a fluid film on each side.

Ref
HTR-01
Rev
v1
Field
Heat Transfer
Result
Q̇ [W]

Series layers carry the same heat rate under steady one-dimensional conduction without generation. Include both fluid films when the specified temperatures are bulk fluid temperatures. The calculator has one wall layer and two films.

Heat flows through the wall and its two surface films like current through resistors in series; the total resistance sets the flow.

Calculator

Solve for
W
°C
0200
°C
−50100
m²
0.1100
m
0.0051
W/(m·K)
0.02400
W/(m²·K)
21,000
W/(m²·K)
21,000
  • Total resistance ΣR0.4 K/W
  • Overall U-value2.5 W/(m²·K)

What drives the result

Each variable is moved across its typical range while the others stay at the values above. The longest bar is the key driver.

Heat rate (W) current value 75 W
AWall areaKey driver
7.57,500
T∞,hHot fluid temperature
−25475
T∞,cCold fluid temperature
−150225
kThermal conductivity
5.77150
LWall thickness
13.6143
h₁Hot-side coefficient
37.599.7
h₂Cold-side coefficient
37.599.7
  • For a 0.10 m wall with k = 0.5 W/(m K) and h = 10 on both sides the total resistance is 0.40 K/W, so a 30 K difference drives 75 W.
  • The biggest resistance dominates: improving a low-resistance layer barely helps.
Chart data as tables

Ranked variables

VariableTypical rangeLowest resultHighest resultSwing (W)Local stepChange in result
A Wall area0.1 to 100 m²7.57,5007,493+10%+10 %
T∞,h Hot fluid temperature0 to 200 °C−25475500+10%+13.3 %
T∞,c Cold fluid temperature−50 to 100 °C−150225375+10%−3.33 %
k Thermal conductivity0.02 to 400 W/(m·K)5.769149.8144+10%+4.76 %
L Wall thickness0.005 to 1 m13.64142.9129.2+10%−4.76 %
h₁ Hot-side coefficient2 to 1,000 W/(m²·K)37.599.6762.17+10%+2.33 %
h₂ Cold-side coefficient2 to 1,000 W/(m²·K)37.599.6762.17+10%+2.33 %

Sweep of Wall thickness

Wall thickness (m)Heat rate (W)
0.005142.9
0.009696136.7
0.0188126.3
0.03646109.9
0.0707187.87
0.137163.26
0.265940.99
0.515724.36
113.64

Sweep one variable

Heat rate (W)Hover, touch, or use the arrow keys on the chart
20406080100120140 0.0050.020.10.5 Wall thickness (m), log scale now 75

Variables and how each one contributes

Q̇

Heat rate

Result · W

What the equation gives you. Everything else feeds it.

T∞,h

Hot fluid temperature

°C · typical 0 to 200

Bulk temperature of the hot fluid. Raises the heat rate.

T∞,c

Cold fluid temperature

°C · typical −50 to 100

Bulk temperature of the cold fluid. Lowers the heat rate.

A

Wall area

m² · typical 0.1 to 100

Area normal to heat flow. Directly proportional.

L

Wall thickness

m · typical 0.005 to 1

Thickness of the wall layer. Raises the wall resistance.

k

Thermal conductivity

W/(m·K) · typical 0.02 to 400

Conductivity of the wall. Lowers the wall resistance.

h₁

Hot-side coefficient

W/(m²·K) · typical 2 to 1,000

Convection coefficient on the hot side. Lowers the film resistance.

h₂

Cold-side coefficient

W/(m²·K) · typical 2 to 1,000

Convection coefficient on the cold side. Lowers the film resistance.

Worked example with the values above

  1. Films: 1/(h₁A) = 0.1 and 1/(h₂A) = 0.1 K/W; wall: L/(kA) = 0.2 K/W.
  2. Total resistance ΣR = 0.4 K/W.
  3. Q = (40 − 10) / 0.4 = 75 W.

Assumptions and limits

  • Steady one-dimensional conduction with no generation.
  • Constant properties.

Common mistakes

  • Forgetting the film resistances.
  • Using the wrong area for each layer.

Statistics and uncertainty

Convection coefficients are uncertain by ±20–30%, which dominates the result when the films carry most of the resistance.

Where it is used

  • Insulation and building-envelope heat loss.
  • Enclosure and equipment thermal design.

Maths you need

  • Conduction: q = −kA dT/dx
  • Series resistances: add like electrical resistors