Library / Foundations: Chemistry / FCH-16
Foundations: Chemistry
Enthalpy change from calorimetry
Heat of reaction from the temperature rise of a solution.
- Ref
- FCH-16
- Rev
- v1
- Field
- Foundations: Chemistry
- Result
- ΔH [kJ/mol]
Q is the heat absorbed by the solution (in J), m its mass in g, c its specific heat capacity (4.18 J g⁻¹ K⁻¹ for water) and n the moles of the limiting reagent. The minus sign makes a temperature rise give a negative (exothermic) ΔH.
A reaction that warms the water has given out energy. The temperature rise tells you how much, and dividing by the moles gives the energy per mole.
Calculator
- Heat absorbed by the solution1.359 kJ
- Heat per gram of solution27.17 J/g
What drives the result
Each variable is moved across its typical range while the others stay at the values above. The longest bar is the key driver.
- Neutralisation of a strong acid with a strong alkali gives about −57 kJ/mol; polystyrene cup losses make the measured value a little lower.
- Heat lost to the surroundings is the main source of error, so insulate the cup and use a lid.
Chart data as tables
Ranked variables
| Variable | Typical range | Lowest result | Highest result | Swing (kJ/mol) | Local step | Change in result |
|---|---|---|---|---|---|---|
| n Moles of limiting reagent | 0.001 to 1 mol | −1,359 | −1.359 | 1,357 | +10% | −9.09 % |
| m Mass of solution | 5 to 500 g | −543.4 | −5.434 | 538 | +10% | +10 % |
| ΔT Temperature rise | 0.1 to 50 K | −418 | −0.836 | 417.2 | +10% | +10 % |
| c Specific heat capacity | 0.1 to 10 J/(g K) | −130 | −1.3 | 128.7 | +10% | +10 % |
Sweep of Temperature rise
| Temperature rise (K) | Enthalpy change (kJ/mol) |
|---|---|
| 0.1 | −0.836 |
| 6.337 | −52.98 |
| 12.57 | −105.1 |
| 18.81 | −157.3 |
| 25.05 | −209.4 |
| 31.29 | −261.6 |
| 37.52 | −313.7 |
| 43.76 | −365.9 |
| 50 | −418 |
Sweep one variable
Variables and how each one contributes
Enthalpy change
What the equation gives you. Everything else feeds it.
Mass of solution
Mass of solution heated (1 cm³ of water ≈ 1 g). Directly proportional to Q.
Specific heat capacity
4.18 for water-based solutions. Directly proportional to Q.
Temperature rise
Rise in temperature of the solution. Directly proportional to Q.
Moles of limiting reagent
Moles of the reagent that is used up. Inversely proportional.
Worked example with the values above
- Q = m c ΔT = 50 × 4.18 × 6.5 = 1,359 J = 1.359 kJ.
- Divide by the moles: 1.359 / 0.025.
- ΔH = −54.34 kJ/mol (negative: exothermic).
Assumptions and limits
- Solution has the properties of water.
- No heat lost to the surroundings.
Common mistakes
- Dividing by the mass of reactants instead of the moles.
- Giving the wrong sign.
Statistics and uncertainty
Heat loss and thermometer reading error (±0.5 K on 6.5 K is 8%) make ΔH from a simple cup experiment uncertain by 5–10%.
Where it is used
- Measuring energy of fuels and reactions.
- Checking neutralisation heats.
Maths you need
- Specific heat capacity: Q = m c ΔT
- Moles: n = c V